Scientific Reports volume 13, Article number: 12575 (2023) Cite this article

174 Accesses

2 Altmetric

Metrics details

Optical tweezers exert a strong trapping force on cells, making it crucial to analyze the movement of trapped cells. The rotation of cells plays a significant role in their swimming patterns, such as in sperm cells. We proposed a fast deep-learning-based method that can automatically determine the projection orientation of ellipsoidal-like cells without additional optical design. This method was utilized for analyzing the planar rotation of trapped sperm cells using an optical tweezer, demonstrating its feasibility in extracting the rotation of the cell head. Furthermore, we employed this method to investigate sperm cell activity by examining variations in sperm rotation rates under different conditions, including temperature and laser output power. Our findings provide evidence for the effectiveness of this method and the rotation analysis method developed may have clinical potential for sperm quality evaluation.

Optical tweezers (OT) have been widely researched for trapping and manipulating micro-particles and microorganisms such as polystyrene beads, yeast cell, sperm and Escherichia coli1,2,3,4. During the reproductive process, sperms need to meet the egg through the female reproductive tract. In this process, sperm with low motility will be screened out by barriers such as cervical mucus5. Extensive research has been conducted on the dynamics of sperm cells trapped in optical tweezers, encompassing studies investigating diverse aspects such as chirality and motility force6,7. This research direction has potential value in the single-sperm quality examination, which is crucial to the assistant reproductive technologies like intracytoplasmic sperm injection (ICSI)8. Currently, the main method for quickly tracking the movement of the head of a sperm cell involves tracking its centroid, which uses traditional clustering algorithms to segment9,10. Then Nascimento et al. employed this method to calculate the curvilinear velocity(VCL) of the head to characterize sperm activity11. However, In the high numerical aperture objective lens field of view, traditional segmentation methods have poor segmentation results due to complex background noise. Besides, for more complex motion patterns of sperm, such as rotation, the additional optical set-up should be designed, and corresponding algorithms to determine the three-dimensional motion of the sperm usually perform relatively slowly12.

Deep learning has been widely applied in the field of medical cell image segmentation, especially for particular cell counting13, liver and liver-tumor segmentation14, brain and brain-tumor segmentation15 etc. And compared with traditional methods, it has superior segmentation performance and robustness16,17.This tool can also be combined with optical tweezers and applied to axial localization of microspheres18, optical force prediction of the optical tweezers19, and trap stiffness measurement20. In this study, we propose highly efficient method that extracting the orientation of the sperm head using deep learning-based segmentation. We combine it with optical tweezers to dynamically trap sperms and analyze the rotational motility of individual sperm directly and simultaneously. This method is also suitable with other ellipsoidal-like cells or bacteria like Escherichia coli. Our experiments analyzed the difference in rotational angular speed of sperm cells at different laser output power and verified that our method has potential applications in clinical research for sperm motility quantification and single sperm motility detection.

To obtain the projection phase information of the sperm, we used a self-designed optical tweezers system as shown in Fig. 1a. In our experimental setup, we employed a continuous wave laser (Coherent Verdi G, 2W) to generate a 532-nm laser beam. This laser beam was directed into a beam shaping system (BSS) for beam expansion. The resulting linear polarized laser beam was then directed onto a dichroic mirror, which reflected it onto the back aperture of an oil immersion microscope objective (Nikon, 100\(\times\) oil immersion; NA = 1.4; WD = 0.13 mm). The beam is modulated through a reflective and pure phase-only liquid crystal spatial light modulator (Holoeye, HED6010-L-VIS) in the shaping system. The sample solution of interest was loaded onto a sample pool and positioned at the back focal plane of the oil mirror, which was controlled using a voltage-controlled stage (Thorlabs; ZFM2030). The illumination of the sample chamber was provided by a LED light source and the imaging of the sample was performed using a CMOS camera (Sentech; STC-mbs241U3V; 163 fps).

The experimental apparatus (a) and the schematic diagram of phase angle extraction (b), the white scale bar represents 10 \(\upmu\)m.

Prior to the experiment, we calibrated the position of the optical trap and used a 150 \(\times\) 150 pixel region around the trap center as the region of interest (ROI) to exclude interference from other swimming sperms, as shown in Fig. 1b. For the extracted image area, we used image segmentation to perform contour detection to obtain the projection phase of the head shape. Then, the rotational angular speed was calculated from the phase difference between consecutive frames.

To achieve faster and more accurate segmentation results, we introduced a deep-learning segmentation algorithm. This is because traditional gray threshold segmentation, such as level set and clustering method, is greatly affected by noise in the segmentation of high-magnification cell images under high-NA lens imaging, as shown in Fig. 2b. Moreover, these methods rely on manual or adaptive adjustment of parameters, which may not be effective in complex scenes. Deep learning-based image segmentation algorithms have become a hot topic in recent years. In this study, we used the U-Net++ network for image segmentation. U-Net++ is a supervised learning network based on the fully convolutional neural network, U-Net. By redesigning the skip connections, it aggregates information features of different semantic scales in the decoder sub-network, forming a highly flexible feature fusion solution, and has performed well on many biological datasets and backbone architectures21. As a type of supervised learning, the training of this model requires a certain amount of data to generate better segmentation results. Figure 2a shows the schematic diagram of our solution. The loss function we used is the hybrid loss which combined the cross-entropy loss and soft dice-coefficient loss. The hybrid loss is defined as22

where \({{y}_{n,c}}\in \text {Y}\) and \({{p}_{n,c}}\in \text {P}\) denotes the target labels and predicted probabilities for class c (here just two classes) and nth pixel in the training batch. Our training dataset consisted of 125 images of trapped sperm cells with a size of 120 \(\times\) 120 pixels and the corresponding manually segmented results. The network depth was set to 4 layers, and the optimal network parameters were calculated using cross-validation. After processing the segmented sperm images, a threshold method can be used for binarization to extract the mask. Despite the small size of the training dataset, the segmentation results are remarkable, particularly when compared to the other two models, as is shown in Fig. 2b, where the intersection over union (IoU) and Dice coefficients can reach around 90%. The IoU and Dice coefficients are defined as follows23, where the S represents the segmented mask and T represents the truth mask. For each of them, a higher value indicates a higher degree of overlap and similarity between the segmentation result and the reference mask

The level set and clustering models in the study utilized modules provided by ImageJ 1.53v24. This approach can achieve rapid and accurate image segmentation in milliseconds by deploying on high-performance GPUs, achieving real-time segmentation, as shown in Table 1. The experiments are performed using NIVIDA GeForce RTX 2080 GPU with 8 GB memory.

Diagram of the model training process (a); showing the training set used for training, including the original image and pre-segmented image, and the image segmentation process below. Qualitative comparison among U-net++, Level set, and Clustering method (b); showing segmented result and final mask output for the trapped sperm. The corresponding quantitative scores are provided at the bottom of each prediction (IoU|Dice). Frames of a sperm trapped at 0 ms, 100 ms, 200 ms, and 300 ms (c), with the original images shown at the top, the segmented images in the middle, and the contour extracted results at the bottom. The green label represents the phase of the fitted ellipse.

The projected orientation of the sperm needs to be determined from the segmented image. The human sperm head is flat and elliptical, with a length of about 4–5 \(\upmu\)m and a width of about 2.5–3.5 \(\upmu\)m25. This elliptical shape is different from the circular shape of typical cells, so the two-dimensional orientation of the sperm can be determined visually. In this study, the elliptical fitting tool provided by OpenCV26 is used to approximate the shape of the sperm head in the grayscale image obtained from the segmented sperm image, and the phase information \(\alpha\) of the head is obtained, as shown in Fig. 1b. Figure 2c depicts a series of images of segmented sperm at four different time points, along with the results of ellipse fitting. It can be observed that the phase is accurately extracted. Despite the fact that the segmented result appears oval when the sperm is in a sideways position, the phase is still acquired accurately. The absolute angular speed is then obtained using the forward difference method, as shown in the following equation,where k means the kth frame, fps denotes the recording rate of 163 frames per second:

The aforementioned methodology was employed to determine the phase value of a rotating sperm under optical trapping control using sperm samples obtained from a single healthy male. The experiment was conducted at a temperature of 23 \(^{\circ }\)C. The laser output power was set to 400 mW. The laser trapping power reaching the sperm can be measured with a power meter and is approximately 120 mW, resulting in a temperature increase of around 1 \(^{\circ }\)C27,28,29. To try to minimize the potential for light-induced damage to the sperm, the capture duration of the trapped sperm was limited to no more than 4 s30. To facilitate comparative analysis, we opted to select three representative sperms for evaluation, namely \(S_0\), \(S_1\), and \(S_2\). \(S_0\) appeared to be inactive under microscopic observation with minimal or no detectable movement, while both \(S_1\) and \(S_2\) exhibited rapid head oscillatory movements in a trapped state contrasting with the dead-like state of \(S_0\). Figure 3a–c,d–f illustrate the phase information and calculated angular speed rate for the three sperm cells mentioned above . It can be seen that for the basically inactive sperm cell, the signal in Fig. 3d shows low-frequency sparsity, while the signal in Fig. 3e,f is high-frequency density. For the angular speed signal, we used a box plot for statistical analysis. The results are shown in Fig. 3g. It can be seen that for \(S_0\), both the mean and median tend to be 0, while for the other two trapped more active sperm cells, their mean and median are relatively larger. Furthermore, we used a two-sample t-test in statistics to determine whether there is a significant difference in the mean angular speed between the two groups. And the results suggest that the rotation activity levels of \(S_2\) sperm were likely higher than those of \(S_1\) sperm, as indicated by a statistically significant p value of less than 0.01. Accordingly, we could select \(S_2\) sperm as the target of our research due to its relatively higher motility levels when compared to \(S_1\) sperm.

Phase angle signal and corresponding angular speed rate for different motilities of sperm \(S_0\) (a,c), \(S_1\) (b,e), and \(S_2\) (c,f) when they are trapped in the OT. Comparison of angular speed rate for sperms before (green data) and after (blue data) they are trapped. Mean values with 25–75% of data are depicted. The significance level was set at **p < 0.01.

In addition, we manually tracked the trajectory of the untrapped sperm (about 40 frames) with the aid of ImageJ24 and used the method of tracking ROI to provide the angular speed of the swimming sperm prior to capture, as shown in Fig. 3f. It can be seen that the speed distribution of the untrapped sperm signal is larger. This is because the sperm will experience the torque of the optical trap during rotation, which will cause the rotation speed to decrease, as shown in the wider range of 25–75% of the swimming group compared to the trapped group. However, the average output power of trapped and untrapped sperm is basically the same.

In order to further confirm the feasibility of the method. We divided the sperm from the same sample into two parts (about 800 \(\upmu\)L each), one was refrigerated at 4 \(^{\circ }\)C for 6 h, and the other was stored at room temperature(23 \(^{\circ }\)C) for 6 h for statistical analysis of the average angular speed at a laser output power of 400 mW. In order to avoid the increase in motility of the refrigerated sperm caused by rewarming as much as possible, we replaced the sample and captured sperms after 5 captures. The results are shown in Fig. 4a. It can be seen that the average activity of refrigerated sperm is reduced by about 30%, which is consistent with the expected decrease in sperm activity after refrigeration. Meanwhile, we chose 300 mW, 400 mW, and 500 mW as the laser output power with other conditions held constant to acquire the angular speed of trapped sperm under different trapping energy potentials. Regarding the temperature increase caused by optical trapping, due to a difference of 30 mW between actual laser trapping powers, the maximum temperature difference induced by different laser powers remains within 1 \(^{\circ }\)C27,28,29. This temperature difference has a minimal impact on the experiment. As shown in Fig. 4b, it can be seen that at these power levels, the sperm can be stably trapped. It is evident that at 400 mW, the trapped sperm have the highest average angular speed and widest distribution range. While at 500 mW and 300 mW, their speeds are relatively low and their ranges narrow. This is probably due to two reasons: the torque exerted on the captured target exhibits a positive correlation with the increase in intensity, which is directly linked to the laser output power31,32. At 500 mW, the resistance torque is too high, resulting in excessive damping of the sperm and limiting its rotation; while at 300 mW, the energy is too low to capture highly active sperm33, resulting in lower captured sperm rotation motility. Therefore, 400 mW is the ideal output power with the largest range of captured sperm rotation motility, and the selected power in practical applications needs to be above the appropriate output power to achieve maximum distinguishability.

Comparison of sperm angular speed at different temperatures (a), with non-refrigerated sperms on the left and refrigerated sperms on the right. Mean values ± SD with 25–75% data (green data and blue dots) are depicted. Comparison of sperm angular speed for different laser output power (b). Mean values ± SD with 25–75% data are depicted. In both of them, n represents the total sample number.

This research paper proposes a deep learning-based method for image segmentation of sperm heads, which enables the dynamic extraction of rotation angular speed as a criterion for optically trapped sperm motility detection. The study demonstrates the reliability of the method by comparing refrigerated and normal sperm samples and identifies the optimal laser power range for maximizing the distinction between sperm. This research provides a strong foundation for subsequent sperm selection using optical tweezers and has a potential for clinical applications such as ICSI, which could improve outcomes for couples facing fertility challenges (Supplementary Information).

The human semen samples were collected from individual patients at the Reproductive Medicine Center, the First Affiliated Hospital of Anhui Medical University. All patients gave informed consent prior to being included in the study. The semen samples were diluted in fertilization medium (Cook Medical, U.S.) and stored at 4 \(^{\circ }\)C for subsequent experiments. Before loading onto the self-built optical tweezers instrument’s sample pool, the sperm samples were further diluted in 20–40 folds with fertilization medium.

All analyses were performed using Origin 2021b. A two-sided P value of \(<0.05\) was considered significant.

The studies involving human participants were reviewed and approved by Biomedical Ethics Committee of Anhui Medical University. The patients/participants provided their written informed consent to participate in this study. All methods were carried out in accordance with the university guidelines and regulations for sperm experimentation.

The datasets used and analysed during the current study available from the corresponding author on reasonable request.

Wang, X. et al. Enhanced cell sorting and manipulation with combined optical tweezer and microfluidic chip technologies. Lab Chip 11, 3656–3662 (2011).

Article CAS PubMed Google Scholar

Ericsson, M., Hanstorp, D., Hagberg, P., Enger, J. & Nystrom, T. Sorting out bacterial viability with optical tweezers. J. Bacteriol. 182, 5551–5555 (2000).

Article CAS PubMed PubMed Central Google Scholar

Enger, J., Goksör, M., Ramser, K., Hagberg, P. & Hanstorp, D. Optical tweezers applied to a microfluidic system. Lab Chip 4, 196–200 (2004).

Article CAS PubMed Google Scholar

Xu, T., Wu, S., Jiang, Z., Wu, X. & Zhang, Q. Regulating trapping energy for multi-object manipulation by random phase encoding. Opt. Lett. 45, 2002–2005 (2020).

Article ADS PubMed Google Scholar

Westphal, L. M., Dansasouri, I. E., Shimizu, S., Tadir, Y. & Berns, M. W. Exposure of human spermatozoa to the cumulus oophorus results in increased relative force as measured by a 760 nm laser optical trap. Hum. Reprod. 8, 1083–1086 (1993).

Article CAS PubMed Google Scholar

Zhong, Z. et al. Chirality and frequency measurement of longitudinal rolling of human sperm using optical trap. Front. Bioeng. Biotechnol. 10, 25 (2022).

Article Google Scholar

König, K. et al. Determination of motility forces of human spermatozoa using an 800 nm optical trap. Cell. Mol. Biol. 42, 501–509 (1996).

PubMed Google Scholar

Devroey, P. & Van Steirteghem, A. A review of ten years experience of icsi. Hum. Reprod. Update 10, 19–28 (2004).

Article CAS PubMed Google Scholar

Shi, Z., Nascimento, L. J., Chandsawangbhuwana, C., Berns, M. W. & Botvinick, E. L. Real-time automated tracking and trapping system for sperm. Microsc. Res. Tech. 69, 894–902 (2006).

Article PubMed Google Scholar

Shi, L. Z., Nascimento, J. M., Berns, M. W. & Botvinick, E. L. Computer-based tracking of single sperm. J. Biomed. Opt. 11, 054009–054009 (2006).

Article ADS PubMed Google Scholar

Amann, R. P. & Waberski, D. Computer-assisted sperm analysis (CASA): Capabilities and potential developments. Theriogenology 81, 5–17 (2014).

Article PubMed Google Scholar

Dardikman-Yoffe, G., Mirsky, S. K., Barnea, I. & Shaked, N. T. High-resolution 4-d acquisition of freely swimming human sperm cells without staining. Sci. Adv. 6, eaay7619 (2020).

Article ADS CAS PubMed PubMed Central Google Scholar

Zhang, J. et al. A comprehensive review of image analysis methods for microorganism counting: From classical image processing to deep learning approaches. Artif. Intell. Rev. 20, 1–70 (2022).

Google Scholar

Dong, X. et al. Liver cancer detection using hybridized fully convolutional neural network based on deep learning framework. IEEE Access 8, 129889–129898 (2020).

Article Google Scholar

Akkus, Z., Galimzianova, A., Hoogi, A., Rubin, D. L. & Erickson, B. J. Deep learning for brain MRI segmentation: State of the art and future directions. J. Digit. Imaging 30, 449–459 (2017).

Article PubMed PubMed Central Google Scholar

Long, F. Microscopy cell nuclei segmentation with enhanced u-net. BMC Bioinform. 21, 1–12 (2020).

Article Google Scholar

Liu, Y. & Long, F. Acute lymphoblastic leukemia cells image analysis with deep bagging ensemble learning. In ISBI 2019 C-NMC Challenge: Classification in Cancer Cell Imaging: Select Proceedings, 113–121 (Springer, 2019).

Guo, M. et al. Deep learning for precise axial localization of trapped microspheres in reflective optical systems. Opt. Express 31, 12397–12409 (2023).

Article ADS PubMed Google Scholar

Lenton, I. C., Volpe, G., Stilgoe, A. B., Nieminen, T. A. & Rubinsztein-Dunlop, H. Machine learning reveals complex behaviours in optically trapped particles. Mach. Learn. Sci. Technol. 1, 045009 (2020).

Article Google Scholar

Dey, R., Ghosh, S., Kundu, A. & Banerjee, A. Simultaneous random number generation and optical tweezers calibration employing a learning algorithm based on the brownian dynamics of a trapped colloidal particle. Front. Phys. 8, 629 (2021).

Article Google Scholar

Zhou, Z., Siddiquee, M. M. R., Tajbakhsh, N. & Liang, J. UNet++: Redesigning skip connections to exploit multiscale features in image segmentation. IEEE Trans. Med. Imaging 39, 1856–1867 (2020).

Article PubMed Google Scholar

Micallef, N., Seychell, D. & Bajada, C. J. Exploring the u-net++ model for automatic brain tumor segmentation. IEEE Access 9, 125523–125539 (2021).

Article Google Scholar

Shvets, A. A., Rakhlin, A., Kalinin, A. A. & Iglovikov, V. I. Automatic instrument segmentation in robot-assisted surgery using deep learning. In 2018 17th IEEE International Conference on Machine Learning and Applications (ICMLA), 624–628 (IEEE, 2018).

Schneider, C. A., Rasband, W. S. & Eliceiri, K. W. Nih image to imagej: 25 years of image analysis. Nat. Methods 9, 671–675 (2012).

Article CAS PubMed PubMed Central Google Scholar

Katigbak, R. D., Turchini, G. M., de Graaf, S. P., Kong, L. & Dumée, L. F. Review on sperm sorting technologies and sperm properties toward new separation methods via the interface of biochemistry and material science. Adv. Biosyst. 3, 1900079 (2019).

Article Google Scholar

Bradski, G. The OpenCV Library. Dr. Dobb’s Journal of Software Tools 20, 20 (2000).

Google Scholar

Liu, Y. et al. Evidence for localized cell heating induced by infrared optical tweezers. Biophys. J . 68, 2137–2144 (1995).

Article CAS PubMed PubMed Central Google Scholar

Liu, Y., Sonek, G., Berns, M. & Tromberg, B. Physiological monitoring of optically trapped cells: Assessing the effects of confinement by 1064-nm laser tweezers using microfluorometry. Biophys. J . 71, 2158–2167 (1996).

Article CAS PubMed PubMed Central Google Scholar

Blázquez-Castro, A. Optical tweezers: Phototoxicity and thermal stress in cells and biomolecules. Micromachines 10, 507 (2019).

Article PubMed PubMed Central Google Scholar

Nascimento, J. M. et al. The use of optical tweezers to study sperm competition and motility in primates. J. R. Soc. Interface 5, 297–302 (2008).

Article PubMed Google Scholar

Leach, J. et al. Comparison of faxén’s correction for a microsphere translating or rotating near a surface. Phys. Rev. E 79, 026301 (2009).

Article ADS CAS Google Scholar

Simpson, S. H. & Hanna, S. Computational study of the optical trapping of ellipsoidal particles. Phys. Rev. A 84, 053808 (2011).

Article ADS Google Scholar

Tadir, Y. et al. Force generated by human sperm correlated to velocity and determined using a laser generated optical trap. Fertil. Steril. 53, 944–947 (1990).

Article CAS PubMed Google Scholar

Download references

The authors gratefully thank the National Natural Science Foundation of China (Grants 12232017, 11627803, 32061160475, and 12222212) for financial support and the First Affiliate Hospital of Anhui Medical University for providing the samples.

CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei, 230027, China

Jiangcheng Zhao, Chuanbiao Bai & Qingchuan Zhang

School of Biomedical Engineering, Anhui Provincial Institute of Translational Medicine, Anhui Medical University, Hefei, 230027, China

Zhiguo Zhang

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

J.Z. conceived and conducted the experiments under the guidance of Q.Z. with the assistance of C.B and Z.Z. The manuscript was written by J.Z. in discussion with all other authors.

Correspondence to Qingchuan Zhang.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Video 1.

Supplementary Video 2.

Supplementary Video 3.

Supplementary Video 4.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Zhao, J., Bai, C., Zhang, Z. et al. Deep learning-based method for analyzing the optically trapped sperm rotation. Sci Rep 13, 12575 (2023). https://doi.org/10.1038/s41598-023-39819-7

Download citation

Received: 18 May 2023

Accepted: 31 July 2023

Published: 03 August 2023

DOI: https://doi.org/10.1038/s41598-023-39819-7